HomeMy WebLinkAbout201802546 MPCity of Little Rock
Department of Planning & Development
723 W Markham Street
Second Floor
LITTLE ROCK Little Rock, AR 72201-1334
Phone: 501-371-4832
www.littlerock.gov/CityDepartments/PIanningAndDevelopment
Mechanical Permit
Permit No: 201802546
Issue Date: 4/6/2018
Expiration Date: 4/06/2019
Permission is given to:
Contractor: Jones Heating & A/C*C Owner: N/A
To perform the following work:
Class of Work: New Construction Valuatlori:d$�E v'. =''f
Sq Ft: 5,741.00
Job Description: ALL NEW MEC** 2 STY SLAB, 4 BED, 3 1/2 BA, KITCHEN, DINE, LIVING, OFFICE,
GAMEROOM, SAFEROOM, 3 CAR GAR, COV POR
Project Number: 201710213
At the following location:
Subdivision/Lot/Block: CHENAL VALLEY, L10 B106
Address: 15 MIRABEL Ct
To be used as (occupancy): One & Two Family Residential
This permit is issued on the express condition that the above work shall conform in at respects to the statements certified
to in the application for such permit, and that all work shall be done in accordance with all applicable zoning, building,
electrical, plumbing and mechanical ordinances of the City of Little Rock and the State of Arkansas.
I or we further agree to abide by the applicable conditions as printed on the permit card. I or we further certify that we have
read and understand the requirements of this permit and that all statements made by us in securing this permit are true
and complete to the best of our knowledge.
Permit Fees:r; : ;,;. 11ii': _; lr: leil i.['
Data Processing $4.00
Mechanical Permit Fees $473.63
Total: $477.63
Issued by: TSTEELE
Licensed Contractor or Owner
For: Charles G. Givens
Building Official
To schedule Mechanical inspections call: 501-918-5292 or 501-918-5282 ,
City of Little Rock "
CITY OF LITTLE ROCK
DEPARTMENT OF PLANNING & DEVELOPMENT
BUILDING CODES DIVISION APPLICATION FOR:
723 WEST MARKHAM, 2ND FL MECHANICAL (HVACR) PERMIT
LITTLE ROCK, AR 72201 .' ` `
PHONE (501) 918-5282 OR (501):91.8-5292� 4
FAX: 501 371-4546
OFFICIAL USE ONLY
PERMITNO.2018 ���L
DATE ISSUE`
ISSUED BY
INSPECTIONS
APPLICANT (Please Check)
❑ WILL CALL ❑ ROUGH
❑SLAB ❑ FINAL
❑OTHER
PROJECT ADDRESS: 15 MIRABEL COURT
LEGAL DESCRIPTION: LOT BLOCK_
OWNERITENANT: HESS CUSTOM CONSTRUCTION
ADDRESS- 1700 GROVE HILL RD. NLR AR 72116
CONTRACTOR: JONES HEATING & AIR
ADDRESS- 520 EDISON AVE. BENTON AR 72015
PROJECT NO.:
SUBDIVISION
IAkSPECTOR'S COMMENT
�A - %jVs
(Same as Building Permit No.)
TELEPHONE: ($011)993=6769
FAk
LICENSE NO' 0132033
TELEPHONE/FAX (601:)'•:T78�33a24
CLASS OF WORK: Z NEW ❑ADDITION ❑REPLACEMENT ❑ ALTERATION []'OUT OF CITY
PROPOSED USE (OCCUPANCY): ❑ COMMERCIAL ❑✓ RESIDENTIAL ❑ MODULAR/MOBILE HOME ❑ BOILER*
SQUARE FEET- 4075 VALUATION: 13,990
Heating/Air ilJlechanicaI Permit Fees:
A. New one and two-family DWELLING Construction - $.0825/sqft (INCLUDES ROUGH_&_FINAL INSPECTIONS)
OTHER OCCUPANCIES
B. Replacements, repairs, alterations and additions and new commercial — heating, ventilation, ductwork, air c.^dnditioping,,.boilers*, and refrigeration
systems shall be as follows:
■ $31.00 for the First $500.00 up to $1,000 plus $5.15 for each additional thousand or fraction -thereof to -and including $500,000.00.
$2,569.86 for the first $500,000 plus $4.10 for each additional thousand or fraction thereof; fo and inc[utiing $1,000,000.
$4,619.65 for the first $1,000,000 plus $3.09 for each additional thousand or fraction thereof;
THESE PRICES INCLUDE ONLY ONE INSPECTION; ADDITIONAL INSPECTIONS ARE.$20.50 EACH:
Minimum fee for any permit shall be $31.00. Additional fee for Data Processing: $4.0a (residential);$6.00 (comm.)
NO. Of Heating Units: 2 NO. Of Air -Conditioning Units: 2 Ductwork:'❑Yes :�'- `'� '❑Io
(ALL DUCCTVIF� ,q I IRESAROUGH INSPECTION)
Commercial Ven' ation System Commercial Re€rigeration Split System''`- -_ ...No. $f`lnspecdons 2
CHECK ONE OR MORE BELOW-
❑r Electric0 Gas Fired OSplit System[] Package Unit []Water Source []Condenser Coil []Condenser ❑ Evaporative Corp ether (r_xplain)
NOTE: BOILER PERMITS ARE ISSUED WITH PROOF OF SPECIAL BOILER LICENSEE :'r;r r=,a_;, N;Cfi i L E 1H1I'J;
Penalties (Working without a permit): Where work for which a permit is required by the 2010 Arkansas Mechanical payment of such triple fee shall not relieve an
person from fufly complying with the requirements of the 2010 Arkansas Mechanical Code in the execution of, the work-norfrom-any penalties prescribed herein ar
no additional permits shall be granted until all fees have been paid.
NOTICE: SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, GAS, PLUMBING AND HVACR WORK.
I hereby certify that the data submitted on or with this application is true and correct. Any deviation from inform9tion contained herein,
Unless approved by the Building Official will render this permit null and void. =
BRYAN O'NEAL
SIGNATURE OF CONTRACTOR, OWNER OR AGENT
04/06/2018
DATE REV
ills
MANUEL J LOAD
Page 1
LOAD CALCULATOR
Project: HESS CUSTOM CONT.
Outdoor Temp`'-
95
Date: 4/6/2018
Indoor Temp.-N
A 70
Area: 15 MIRABELL COURT
Temp: Difference,
SENSIBLE LOAD CALCULATIONS
GLASS BTU GAIN
_
Direction Area Sq. Ft.
Single
Double
SP BTU Gain
DP BTU Gain
N 124
37
26
4588 " -' `
` • 3224
NE&NW 0
70
56
0
0
E&W 241
95
76
22895
18316
SE&SW 0
82
66
0
0
S 123
52
41
6396
5043
TOTALS 488
TOTALS
33879
26583
DOORS & STAIRWELL BTU GAIN
# Doors Area Sq. Ft.
Factor
Stairwells
Door BTU,Gain
Stairwell BTU Loss
4 146
9.6
1
14fl
ON
TOTALS;
.7402
'NI
WALLS BTU GAIN
Wall Length
488
_., t,. E _ ' t
c p B-: ! ,
Wall Height
10
Total Wall Sq. Ft.
4880
Net Wall Sq. Ft.
4246
Frame Walls R Value
Net Sq Ft
Factor
F Wall BTU Gain
No Insulation
0
7.8
0
R-11
0
2.6
0
R-13
4880
2.3
11224
R-13+1" Polystyrene
0
1.7
=.: �,�
S',. ,ti-: 0
R-19+1/2" Polystyrene
0
1.6
-'TOTALS "'
?1224
Masonry Walls R Value
Net Sq Ft
Factor
"
M' Wali gTU Gain
No Insulation
0
10.9
0
R-5
0
3.1
-0
R-11
0
1.6
0
R-19
0
1
0
TOTALS
- 0
SP Glass Sensible Heat Gain Subtotal
52505
DP Glass Sensible Heat Gain Subtotal
45209
Page 2
CEILING BTU GAIN
Ceiling R Value
Net Sq Ft
Factor
Ceiling BTU Gain
No Insulation
0
21.4
0
R-11
0
4.1 x:.
0
R-19
0
2.6
0
R-30
0
1.6
".0
R-38
3390
1.3
4407
TOTALS
4407
FLOOR BTU GAIN
Floor R Value
Net Sq Ft
Factor
'Floor BTU Gain
No Insulation
3390
7.7
26103
Carpet No Insulation
0
5.1
0
R-11
0
1.7
0
R-19
0
1.1
0
R-30
0
0.7
0
TOTALS
INFILTRATION/VENTILATION BTU GAIN
Factor
�i`4BT6 Gain
Sq. Ft. 0
Cu. Ft.
0
Ceiling Ht. 0
CFM
0 27
0
Mechanical Ventilation
CFM
50 27
11350
TOTALS !'
-1350
INTERNAL BTU GAIN
Factor
Internal BTU Gain
# People 6
300
.,1Boo
# Kitchens 1
1200
� 200
#Computers 2
500
1000
Other 0
0
0
TOTALS
4000
SP a6 TOTALS
' 88365
DP SUB TOTALS
81069
DUCT BTU GAIN
Factor
Duct BTU Gain
R-4 Insulation
0.1
982
SP TOTAL SENSIBLE HEAT. GAIN
89346
DP TOTAL SENSIBLE HEAT GAIN
82050
LATENT
LOAD CALCULATIONS
Latent Load Infiltratrion
i 0
Latent Load Ventilation
1700
# People
6
-1380
TOTALS
3080
Tons Req. 7.7
SP Windows
Total BTU's Required With SP Windows
92426
Tons Req. 7.1
DP windows
Total BTU's Required With DP Windows
85130
.1