Mechanical Permit �;,
Permit No: 201802110
Issue Date: 3/22/2018
Expiration Date: 3/22/2019
Permission is given to:
Contractor: Seaton Heating & Air*
To perform the following work:
Class of Work: New Construction
Sq Ft: 2,675.00
Job Description: ALL NEW MECHANICAL
1ST,SLAB,3BED,2BA,LIV,DIN,KIT,2CAR,PORCHES
Project Number: 201707576
At the following location:
Subdivision/Lot/Block: WILDWOOD PLACE L13 B5
Address: 3 CROSSWOOD Ct
Owner: N/A t'
Valuation IOJ"";ic ;_r;&;1i
To be used as (occupancy): One & Two Family Residential
This permit is issued on the express condition that the above work shall conform in al respects to the statements certified
to in the application for such permit, and that all work shall be done in accordance with all applicable zoning, building,
electrical, plumbing and mechanical ordinances of the City of Little Rock and the State of Arkansas.
I or we further agree to abide by the applicable conditions as printed on the permit card. I or we further certify that we have
read and understand the requirements of this permit and that all statements made by us in securing this permit are true
and complete to the best of our knowledge.
Permit Fees:
Data Processing $4.00
Mechanical Permit Fees $220.69
Total: $224.69
Issued by: SSTEELE
Licensed Contractor or Owner
For: Charles G. Givens
Building Official
To schedule Mechanical inspections call: 501-918-5292 or 501-918-5282..
U , Arc IF, ;a, -
City of Little Rock
Ist
CITY OF LITTLE ROCK
DEPARTMENT OF PLANNING & DEVELOPMENT
BUILDING CODES DIVISION APPLICATIO OR:
723 WEST MARKHAM, 2ND FL MECHANICAL (HVACR) PERMIT
LITTLE ROCK, AR 72201
PHONE (501) 918-5282 OR (501) 918-5292
FAX: 501 1 371-4546
INSPECTIONS
INSPECTOR'S COMMENTS
OFFICIAL USE ONLY
APPLICANT (Please Check)
0 — A _")' I
PERMIT NO. 2018 � [I
Z WILL CALL ❑ ROUGH
DATE ISSUED
❑SLAB ❑FINAL
ISSUED BY
❑OTHER
PROJECT ADDRESS: 3 CrosSWOod Ct
LEGAL DESCRIPTION: LOT.
OWNER/TENANT: Love Construction
3 Crosswood Ct
CONTRACTOR: Seaton Heat N' Air
2000 Lantrip Rd
PROJECT NO.:
BLOCK SUBDIVIS
CLASS OF WORK: Z NEW ❑ADDITION []REPLACEMENT
PROPOSED USE (OCCUPANCY): ❑COMMERCIAL ❑✓ RESIDENTIAL
SQUARE FEET:
VALUA
(Same as Building Permit No.)
TELEPHONE: (5'01`)',24 -'5617
LICENSE NO.: On fIle�
TELEPHONE/FAX (501�)834; 26�10
LT T ❑C3uT F CITY
MODULAR/MOBILA {yam
Heating/Air-ge—chanical Permit Fees: 1
A. New one and two-family DWELLING Construction - $.0825/sqft (INCLUDES ROUGH & FINAL. INSPECTIONS)
OTHER OCCUPANCIES
B. Replacements, repairs, alterations and additions and new commercial — heating, ventilation, ductwork, air conditioning, boilers*, and refrigeration
systems shall be as follows:
• $31.00 Far the first $500.00 up to $1,000 plus $5A6 for each additional thousand or fraction thereof to -and including $500,000.00.
$2,569.85 for the first $500,000 plus $4.10 for each additional thousand or fraction thereof, to aril incf 6u ing $1,000,000.
• $4,619.85 for the first $1,000,000 plus $3.09 for each additional thousand or fraction thereof,
THESE PRICES INCLUDE ONLY ONE INSPECTION; ADDITIONAL INSPECTIONS ARE $20.50 EACH:
Minimum fee for any permit shall be $31.00. Additional fee for Data Processing: $4.00,(residentiaI)$8:00--(comm.)
NO. Of Heating Units: NO. Of Air -Conditioning Units: 1 Ductwork: ❑Yes ,. — R1No
(ALL DUCTIMORKIR' EQUIRr=S A ROUGH INSPECTIOM
Commercial Ventilation System Commercial Refrigeration Split System 14o_.Of. inspections
CHECK ONE OR MORE BELOW: `�
❑Electric❑Gas Fired ❑✓ Split System[] Package Unit❑Water Source ❑Condenser Coil ❑✓ Condenser ❑Evaporative Coi�;6�7`iher (Explain)
NOTE: BOILER PERMITS ARE ISSUED WITH PROOF OF SPECIAL BOILER LICENSE
Penalties [Working without a permit): Where work for which a permit is required by the 2010 Arkansas Mechanical payment of such triple fee shall not relieve an
person from fully complying with the requirements of the 2010 Arkansas Mechanical Code in the execution of the work nor from anypenalties prescribed herein ar
no additional permits shall be granted until all fees have been paid.
NOTICE: SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, GAS, PLUMBING AND HVACR WORK.
I hereby certify that the data submitted on or with this application is true and correct. Any deviation from information contained herein,
Unless approved by the Building Official will render this permit null and void.
Chris Seaton
SIGNATURE OF CONTRACTOR, OWNER OR AGENT
03/15/2018
DATE . ' REV 1115
+ wr ightsoft. Load Short Form
House Core
Seaton
For:
-" -- Job:- Sharlow Lot 52
Feb 20, 2018
By:
Design
Information
Htg
Clg
Infiltration
Outside db ('F)
22
97
Method
Simplified
Ins ide db ('F)
70
75
Construction quality
Average
Design TD ('F)
48
22
Fireplaces r,.... = I
1 (Average)
Daily range
-
M
, f
- et
Inside humidity (%)
30
50
Moisture difference (gr/lb)
20
48
HEATING EQUIPMENT
COOLING EQUIPMENT
Make n/a
Make n/a ; '"' '
Trade n/a
Trade n/a
Model n/a
Cond n/a
AHRI ref. n/a
Coil n/a
AHRI ref. n/a
Efficiency
n/a
Efficiency
n/a
Heating input
Sensible cooling
0
Btuh
Heating output
0
Btuh
Latent cooling
0
Btuh
Temperature rise
0
'F
Total cooling =
0
Btuh
Actual air flow
0
cfm
Actual air flow
0
cfm
Air flow factor
0
cfm/Btuh
Air flow factor
S0
cfm/Btuh
Static pressure
0
in H2O
Static pressure
0
in H2O
Space thermostat
n/a
Load sensible heat ratio
d',
10
ROOM NAME
Area
(ftz)
Htg load
(Btuh)
Clg load^'"�"4c "
(Btuh)
Htg'AVF'
Clg AVF
(cfm)
Laundry
204
5045
3818
133
183
Bedroom 2/Bath
293
5757
2522
151
121
Bedroom 3/Bath
244
5928
3275
156
157
Bedroom 4
188
4525
3192
1'1-
153
Breakfast
165
11122
6841
292
327
Kitchen
270
3163
7048
83
337
Family Room
600
9738
3814
256
182
Dining Room
133
� .1
5515
1726
-1.45
14924
83
I OA
Calculations approved by ACCA to meet all requirements of Manual J-7th Ed.
Wri h1�94fEW ; �t"AClz' 2018-Mar-21 16:29:15
9. Right -Suite® Universal 2017 17.0.23 RSU14073 Page 1
..bfort\Desktop\Loads\Seaton -Sharlow Lot 52.rup Calc = MJ7 Front Door faces: E ...
House Core p
2243
57168
34203
1503
1636
Other equip loads
0
0
Equip. @ 1.02 RSM
34784
Latent cooling
5651`
nn �nI
e74G0
AnAOC
I 4xwl
' 1RIAA
i
-
t.
l
' -7
L5-
i
?r
j
-.,r.-.
Calculations approved by ACCA to meet all requirements�of.ManUal J 7th Ed.. j
2018-Mar-21 16:29:15
wrights0ft Right -Suite® Universal 2017 17.0.23 RSU14073 Paget
ACCk ...bfort\Desktop\Loads\Seaton - Sharlow Lot 52.rup Calc = MR Front Door faces: E
Project Summary Sharlow
t52
�vrightaoft House Core Feb 201
Seaton
Project Information
For:
Notes: Ed's Supply is not responsible for the final outcome of the load provided. This is an estimate
based on the information we were given at a set temperature. Circumstances and degree of
comfort will vary. The contractor has the final say and is responsible for the job.
Weather: Little Rock AFB AR US
b:
I
Winter Design Conditions
Summer Design conditions
Outside db
22 OF
Outside db r , ,., : ,; ;'i. = ,
97
OF
Inside db
70 OF
Inside db _ _. -.
--75
OF
Design TD
48 OF
Design TD
22
OF
Daily range
M
Relative humidity
- '.
50
%
Moisture difference .
7 48.
gr/lb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure
54446 Btuh
Structure
27903
Btuh
Ducts
2722 Btuh
Ducts
2790
Btuh
Central vent (0 cfm)
0 Btuh
Central vent (0 cfm)
0
Btuh
Fr;'^.''..ideo.
i N• .
Humidification
0 Btuh
Blower ,:.,, - ac.. C;i ::�rri :::.nce
0
Btuh
Piping
Equipment load
0 Btuh
57168 Btuh
Use manufacturer's data IDS '
n
Rate/swing multiplier .
load;.
1.02
34784
Btuh
Infiltration
Equipment sensible
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
1 (Average)
Structure
5651
Btuh
Ducts � �
0
� �' �
Btuh
Central vent (0 cfm)
0
Btuh
HeatinCoolin
g
Area (ft2)
2243 2243g
Equipment latent load
5651
Btuh
Volume (ft')
22577 22577
Air changes/hour
0.91 0.41
Equipment Total Load (Sen+.Lat) ..
40435
Btuh
Equiv. AVF (cfm)
343 153
Req. total capacity at 0,70 SHR
4.1
ton
Heating Equipment
Summary
Cooling Equipment -Summary
Make n/a
Make n/a
Trade n/a
Trade n/a
279t,
Model n/a
Cond n/a
AHRI ref. n/a
Coil n/a )
AHRI ref. n/a
Efficiency
n/a
Efficiencyn/a
Heating input
Sensible cooling
0
Btuh
Heating output
0 Btuh
Latent cooling
0
Btuh
Temperature rise
0 OF
Total cooling
i. 0
Btuh
Actual air flow
0 cfm
Actual air flow
14'. 0
cfm
Air flow factor
0 cfm/Btuh
Air flow factor
0
cfm/Btuh
Static pressure
0 in H2O
Static pressure ti' ric:
+: `_. 0
in H2O
Space thermostat
n/a
Load sensible heat ratio
0
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
2018-Mar-21 16:29:15
_ wrightsofll:'
Right -Suite® Universal 2017 17.0.23 RSU14073
Pagel
...bfort\Desktop\Leads\Seaton - Sharlow Lot 52.rup Calc = MJ7 Front Door faces: E