Loading...
HomeMy WebLinkAbout201802110 MPCity of Little Rock Department of Planning & Development 723 W Markham Street Second Floor City,Rof LTTLE ROCK Little Rock, AR 72201-1334 Phone: 501-371-4832 www.littlerock.gov/CityDepartments/PlanningAndDevelopment Mechanical Permit �;, Permit No: 201802110 Issue Date: 3/22/2018 Expiration Date: 3/22/2019 Permission is given to: Contractor: Seaton Heating & Air* To perform the following work: Class of Work: New Construction Sq Ft: 2,675.00 Job Description: ALL NEW MECHANICAL 1ST,SLAB,3BED,2BA,LIV,DIN,KIT,2CAR,PORCHES Project Number: 201707576 At the following location: Subdivision/Lot/Block: WILDWOOD PLACE L13 B5 Address: 3 CROSSWOOD Ct Owner: N/A t' Valuation IOJ"";ic ;_r;&;1i To be used as (occupancy): One & Two Family Residential This permit is issued on the express condition that the above work shall conform in al respects to the statements certified to in the application for such permit, and that all work shall be done in accordance with all applicable zoning, building, electrical, plumbing and mechanical ordinances of the City of Little Rock and the State of Arkansas. I or we further agree to abide by the applicable conditions as printed on the permit card. I or we further certify that we have read and understand the requirements of this permit and that all statements made by us in securing this permit are true and complete to the best of our knowledge. Permit Fees: Data Processing $4.00 Mechanical Permit Fees $220.69 Total: $224.69 Issued by: SSTEELE Licensed Contractor or Owner For: Charles G. Givens Building Official To schedule Mechanical inspections call: 501-918-5292 or 501-918-5282.. U , Arc IF, ;a, - City of Little Rock Ist CITY OF LITTLE ROCK DEPARTMENT OF PLANNING & DEVELOPMENT BUILDING CODES DIVISION APPLICATIO OR: 723 WEST MARKHAM, 2ND FL MECHANICAL (HVACR) PERMIT LITTLE ROCK, AR 72201 PHONE (501) 918-5282 OR (501) 918-5292 FAX: 501 1 371-4546 INSPECTIONS INSPECTOR'S COMMENTS OFFICIAL USE ONLY APPLICANT (Please Check) 0 — A _")' I PERMIT NO. 2018 � [I Z WILL CALL ❑ ROUGH DATE ISSUED ❑SLAB ❑FINAL ISSUED BY ❑OTHER PROJECT ADDRESS: 3 CrosSWOod Ct LEGAL DESCRIPTION: LOT. OWNER/TENANT: Love Construction 3 Crosswood Ct CONTRACTOR: Seaton Heat N' Air 2000 Lantrip Rd PROJECT NO.: BLOCK SUBDIVIS CLASS OF WORK: Z NEW ❑ADDITION []REPLACEMENT PROPOSED USE (OCCUPANCY): ❑COMMERCIAL ❑✓ RESIDENTIAL SQUARE FEET: VALUA (Same as Building Permit No.) TELEPHONE: (5'01`)',24 -'5617 LICENSE NO.: On fIle� TELEPHONE/FAX (501�)834; 26�10 LT T ❑C3uT F CITY MODULAR/MOBILA {yam Heating/Air-ge—chanical Permit Fees: 1 A. New one and two-family DWELLING Construction - $.0825/sqft (INCLUDES ROUGH & FINAL. INSPECTIONS) OTHER OCCUPANCIES B. Replacements, repairs, alterations and additions and new commercial — heating, ventilation, ductwork, air conditioning, boilers*, and refrigeration systems shall be as follows: • $31.00 Far the first $500.00 up to $1,000 plus $5A6 for each additional thousand or fraction thereof to -and including $500,000.00. $2,569.85 for the first $500,000 plus $4.10 for each additional thousand or fraction thereof, to aril incf 6u ing $1,000,000. • $4,619.85 for the first $1,000,000 plus $3.09 for each additional thousand or fraction thereof, THESE PRICES INCLUDE ONLY ONE INSPECTION; ADDITIONAL INSPECTIONS ARE $20.50 EACH: Minimum fee for any permit shall be $31.00. Additional fee for Data Processing: $4.00,(residentiaI)$8:00--(comm.) NO. Of Heating Units: NO. Of Air -Conditioning Units: 1 Ductwork: ❑Yes ,. — R1No (ALL DUCTIMORKIR' EQUIRr=S A ROUGH INSPECTIOM Commercial Ventilation System Commercial Refrigeration Split System 14o_.Of. inspections CHECK ONE OR MORE BELOW: `� ❑Electric❑Gas Fired ❑✓ Split System[] Package Unit❑Water Source ❑Condenser Coil ❑✓ Condenser ❑Evaporative Coi�;6�7`iher (Explain) NOTE: BOILER PERMITS ARE ISSUED WITH PROOF OF SPECIAL BOILER LICENSE Penalties [Working without a permit): Where work for which a permit is required by the 2010 Arkansas Mechanical payment of such triple fee shall not relieve an person from fully complying with the requirements of the 2010 Arkansas Mechanical Code in the execution of the work nor from anypenalties prescribed herein ar no additional permits shall be granted until all fees have been paid. NOTICE: SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, GAS, PLUMBING AND HVACR WORK. I hereby certify that the data submitted on or with this application is true and correct. Any deviation from information contained herein, Unless approved by the Building Official will render this permit null and void. Chris Seaton SIGNATURE OF CONTRACTOR, OWNER OR AGENT 03/15/2018 DATE . ' REV 1115 + wr ightsoft. Load Short Form House Core Seaton For: -" -- Job:- Sharlow Lot 52 Feb 20, 2018 By: Design Information Htg Clg Infiltration Outside db ('F) 22 97 Method Simplified Ins ide db ('F) 70 75 Construction quality Average Design TD ('F) 48 22 Fireplaces r,.... = I 1 (Average) Daily range - M , f - et Inside humidity (%) 30 50 Moisture difference (gr/lb) 20 48 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a ; '"' ' Trade n/a Trade n/a Model n/a Cond n/a AHRI ref. n/a Coil n/a AHRI ref. n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 'F Total cooling = 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor S0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio d', 10 ROOM NAME Area (ftz) Htg load (Btuh) Clg load^'"�"4c " (Btuh) Htg'AVF' Clg AVF (cfm) Laundry 204 5045 3818 133 183 Bedroom 2/Bath 293 5757 2522 151 121 Bedroom 3/Bath 244 5928 3275 156 157 Bedroom 4 188 4525 3192 1'1- 153 Breakfast 165 11122 6841 292 327 Kitchen 270 3163 7048 83 337 Family Room 600 9738 3814 256 182 Dining Room 133 � .1 5515 1726 -1.45 14924 83 I OA Calculations approved by ACCA to meet all requirements of Manual J-7th Ed. Wri h1�94fEW ; �t"AClz' 2018-Mar-21 16:29:15 9. Right -Suite® Universal 2017 17.0.23 RSU14073 Page 1 ..bfort\Desktop\Loads\Seaton -Sharlow Lot 52.rup Calc = MJ7 Front Door faces: E ... House Core p 2243 57168 34203 1503 1636 Other equip loads 0 0 Equip. @ 1.02 RSM 34784 Latent cooling 5651` nn �nI e74G0 AnAOC I 4xwl ' 1RIAA i - t. l ' -7 L5- i ?r j -.,r.-. Calculations approved by ACCA to meet all requirements�of.ManUal J 7th Ed.. j 2018-Mar-21 16:29:15 wrights0ft Right -Suite® Universal 2017 17.0.23 RSU14073 Paget ACCk ...bfort\Desktop\Loads\Seaton - Sharlow Lot 52.rup Calc = MR Front Door faces: E Project Summary Sharlow t52 �vrightaoft House Core Feb 201 Seaton Project Information For: Notes: Ed's Supply is not responsible for the final outcome of the load provided. This is an estimate based on the information we were given at a set temperature. Circumstances and degree of comfort will vary. The contractor has the final say and is responsible for the job. Weather: Little Rock AFB AR US b: I Winter Design Conditions Summer Design conditions Outside db 22 OF Outside db r , ,., : ,; ;'i. = , 97 OF Inside db 70 OF Inside db _ _. -. --75 OF Design TD 48 OF Design TD 22 OF Daily range M Relative humidity - '. 50 % Moisture difference . 7 48. gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 54446 Btuh Structure 27903 Btuh Ducts 2722 Btuh Ducts 2790 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Fr;'^.''..ideo. i N• . Humidification 0 Btuh Blower ,:.,, - ac.. C;i ::�rri :::.nce 0 Btuh Piping Equipment load 0 Btuh 57168 Btuh Use manufacturer's data IDS ' n Rate/swing multiplier . load;. 1.02 34784 Btuh Infiltration Equipment sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 5651 Btuh Ducts � � 0 � �' � Btuh Central vent (0 cfm) 0 Btuh HeatinCoolin g Area (ft2) 2243 2243g Equipment latent load 5651 Btuh Volume (ft') 22577 22577 Air changes/hour 0.91 0.41 Equipment Total Load (Sen+.Lat) .. 40435 Btuh Equiv. AVF (cfm) 343 153 Req. total capacity at 0,70 SHR 4.1 ton Heating Equipment Summary Cooling Equipment -Summary Make n/a Make n/a Trade n/a Trade n/a 279t, Model n/a Cond n/a AHRI ref. n/a Coil n/a ) AHRI ref. n/a Efficiency n/a Efficiencyn/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 OF Total cooling i. 0 Btuh Actual air flow 0 cfm Actual air flow 14'. 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure ti' ric: +: `_. 0 in H2O Space thermostat n/a Load sensible heat ratio 0 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. 2018-Mar-21 16:29:15 _ wrightsofll:' Right -Suite® Universal 2017 17.0.23 RSU14073 Pagel ...bfort\Desktop\Leads\Seaton - Sharlow Lot 52.rup Calc = MJ7 Front Door faces: E