Mechanical Permit
Permit No: 201800913
Issue Date: 2/5/2018
Expiration Date: 2/05/2019
Permission is given to:
Contractor: Jones Heating & A/C*C Owner: N/A
To perform the following work:
Class of Work: Alteration to Exist Valuation:: $8,200
Job Description: H&A UNITS, DUCT, 2 INSP
COUNTERTOPS, APPLIANCES, SHEETROCK, ROOFING
Project Number: 201710512
At the following location:
Subdivision/Lot/Block:
Address: 2806 W DAISY L GATSON BATES DR
Little Rock, AR 72202-4342
To be used as (occupancy): One & Two Family Residential
This permit is issued on the express condition that the above work shall conform in al respects to the statements certified
to in the application for such permit, and that all work shall be done in accordance with all applicable zoning, building,
electrical, plumbing and mechanical ordinances of the City of Little Rock and the State of Arkansas.
I or we further agree to abide by the applicable conditions as printed on the permit card. I or we further certify that we have
read and understand the requirements of this permit and that all statements made by us in securing this permit are true
and complete to the best of our knowledge.
Permit Fees:
Data Processing $4.00
Mechanical Permit Fees $31.00
Total: $35.00
Issued by: SSTEELE
Licensed Contractor or Owner
For: Charles G. Givens
Building Official
To schedule Mechanical inspections call: 501-918-5292 or 501-918-5282
City of Little Rock
EKCITY OF LITTLE ROCK
DEPARTMENT OF PLANNING & DEVELOPMENT
BUILDING CODES DIVISION APPLICATION FOR:
723 WEST MARKHAM, 2ND FL MECHANICAL (HVACR) PERMIT
LITTLE ROCK, AR 72201
PHONE (501) 918-5282 OR (501) 918-5292
FAX: 5 01 371-4546
INSPECTIONS INSPECTOR'S COMMENTS
OFFICIAL USE ONLY APPLICANT (Please Check)
PERMIT N0.201g ()CA I3
[:]WILLCALL ❑ROUGH
DATE ISSUED IZL511 1
l5 ❑SLAB ❑ FINAL
ISSUED BYS ❑OTHER
PROJECT ADDRESS: 2806 DAISY L GASTON BATES DR. PROJECT NO.
LEGAL DESCRIPTION' LOT BLOCK
OWNER/TENANT:
(Same as Building Permit No.)
SUBDIVISION
TELEPHONE: (�01) 993-6323
s i
ADDREIs. 23419 GREYSTONE MANOR DR. LR AR 72223 FAX:
CONTRACTOR: JONES HEATING & AIR LICENSE NO.:
TURNER & SON CONSTRUCTION
520 EDISON BENTON AR 72015
CLASS OF WORK: []NEW ❑ADDITION []REPLACEMENT
PROPOSED USE (OCCUPANCY): I__I COMMERCIAL ❑ RESIDENTIAL
133032
TELEPHONE/FAX (50T)'778-3324
❑ ALTERATION 11 [-]OUT OF CITY
❑ MODULAR/MOBILE HOME ❑ BOILER -
SQUARE FEET- 1450 VALUATION: 8,200
Heating/Air Mechanical Permit Fees:
A. New one and two-family DWELLING Construction - $.0825/sqft (INCLUDES ROUGH_& FINAL INSPECTIONS)
OTHER OCCUPANCIES
B. Replacements, repairs, alterations and additions and new commercial -- heating, ventilation, ductwork, air conditioning, ,oilers', and refrigeration
systems shall be as follows:
$31.00 for the first $500.00 up to $1,000 plus $5.15 for each addit€anal thousand or fraction thereof to -and including $500,000.00.
$2,569.85 for the first $600,000 plus $4.10 for each additional thousand or fraction thereof, yo A ihclvoing $1,000,000.
• $4,619.86 for the first $1,000,000 plus $3.09 for each additional thousand or fraction thereof
THESE PRICES INCLUDE ONLY ONE INSPECTION; ADDITIONAL INSPECTIONS ARE $20.50 EACH:
Minimum fee for any permit shall be $31.00. Additional fee for Data Processing: $4.00 (resident€al),$6.00 (comm.)
NO. Of Heating Units: 2 NO. Of Air -Conditioning Units- 2 Ductwork: QYes f ❑ No
(ALL DUCTWORK REQUIRES A ROUGH INSPEC770llfy
Commercial Ventilation System Commercial Refrigeration Split System No. Of Inspections P
CHECK ONE OR MORE BELOW:
DElectricOGas Fired ❑r Split System❑Package Unit❑Water Source ❑Condenser Coil[]Condenser ❑Evaporative Coll []Other (Explain)
NOTE: BOILER PERMITS ARE ISSUED WITH PROOF OF SPECIAL BOILER LICENSE
Penalties (Working without a permit): Where work for which a permit is required by the 2010 Arkansas Mechanical payment of such triple fee shall not relieve an
person from fully complying with the requirements of the 2010 Arkansas Mechanical Code in the execution of the work nor from any penalties prescribed herein ar
no additional permits shall be granted unfit all fees have been paid.
NOTICE: SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, GAS, PLUMBING AND HVACR WORK.
I hereby certify that the data submitted on or with this application is true and correct Any deviation from information cpntained herein,
Unless approved by the Building Official will render this permit null and void.
BRYAN O'NEAL
SIGNATURE OF CONTRACTOR, OWNER OR AGENT
02/05/2018:
DATE REV 1115
r:
Ceiling R Value
No Insulation
R-11
R-19
R-30
R-38
Floor R Value
No Insulation
Carpet No Insulation
R-11
R-19
R-30
Sq. Ft. 0
Ceiling Ht. 0
Mechanical Ventilation
# People
# Kitchens
#Computers
Other
R-4 Insulation
CEILING BTU GAIN
Net Sq Ft
Factor
0
21.4
0
4.1
0
2.6
1450
1.6
0
1.3
TOTALS
FLOOR BTU GAIN
Net Sq Ft
Factor
720
7.7
0
5.1
0
1.7
0
1.1
0
0.7
TOTALS
INFILTRATIONIVENTILATION BTU GAIN
Factor
Cu. Ft.
0
CFM
0 27
CFM
50 27
TOTALS
INTERNAL BTU GAIN
Factor
300
1200
500
Factor
0.1
TOTALS
SP SUB TOTALS
DP SUB TOTALS
DUCT BTU GAIN
SP TOTAL SENSIBLE HEAT GAIN
DP TOTAL SENSIBLE HEAT GAIN
LATENT LOAD CALCULATIONS
Latent Load Infiltratrion
Latent Load Ventilation
# People 2
Tons Req, 4.0 SP Windows
Tons Req, 3.7 DP windows
TOTALS
Total BTU's Required With SP Windows
Total BTU's Required With DP Windows
Page 2
Ceiling BTU Gain
0
0
0
2320
0
i- 32,0
Floor BTU Gain
5544
0
0
0
0
5544
I / V BTU Gain
0
1350
.1350
In.tiernal BTU Gain
900
1200
0
0
2100
45673
41182
Duct BTU Gain
5.07
46181
41690
0
1:700
1460
2160
48341
43850
MANUEL J LOAD
Page 1
LOAD CALCULATOR
Project: TURNER & SON
CONST.
Outdoor Temp.':
95
Date: 2/5/2018
Indoor Temp.
70
Area: 2806 DAISY L GASTON
BATES DR.
Temp. Difference
25
SENSIBLE LOAD CALCULATIONS
GLASS BTU GAIN
Direction Area Sq. Ft.
Single
Double
SP BTU Gain
DP BTU Gain
N 96
37
26
3552
2496
NE&NW 0
70
56
0
0
E&W 131
95
76
12445
9956
SE&SW 0
82
66
0
0
S 86
52
41
4472
3526
TOTALS 313
TOTALS
20469
15978
DOORS & STAIRWELL BTU GAIN
# Doors Area Sq. Ft.
Factor
Stairwells
Door BTU Gain.
Stairwell BTU Loss
2 72
9.6
1
.691
6000
TOTALS
6691
WALLS BTU GAIN
Wall Length
313
Wall Height
10
Total Wall Sq. Ft.
3130
Net Wall Sq. Ft.
2745
Frame Walls R Value
Net Sq Ft
Factor
F Wall; 8TU Gain
No Insulation
0
7.8
0
R-11
0
2.6
`-0
R-13
3130
2.3
7199
R-13+1" Polystyrene
0
1.7
; �1. 0
R-19+1 /2" Polystyrene
1.6
0
TOTALS
7199
Masonry Walls R Value
Net Sq Ft
Factor
M Wall BTU Gain
No Insulation
0
10•9
0
R-5
0
3.1
0
R-11
0
1.6
0
R-19
0
1
0
TOTALS
0
SP Glass Sensible Heat Gain Subtotal
34359
DP Glass Sensible Heat Gain Subtotal
29868