HomeMy WebLinkAbout201800913 MPCity of Little Rock Department of Planning & Development 723 W Markham Street Second Floor LITTLE Little Rock, AR 72201-1334 ROCK Phone: 501-371-4832 www.littlerock.gov/CityDepartments/PlanningAndDevelopment Mechanical Permit Permit No: 201800913 Issue Date: 2/5/2018 Expiration Date: 2/05/2019 Permission is given to: Contractor: Jones Heating & A/C*C Owner: N/A To perform the following work: Class of Work: Alteration to Exist Valuation:: $8,200 Job Description: H&A UNITS, DUCT, 2 INSP COUNTERTOPS, APPLIANCES, SHEETROCK, ROOFING Project Number: 201710512 At the following location: Subdivision/Lot/Block: Address: 2806 W DAISY L GATSON BATES DR Little Rock, AR 72202-4342 To be used as (occupancy): One & Two Family Residential This permit is issued on the express condition that the above work shall conform in al respects to the statements certified to in the application for such permit, and that all work shall be done in accordance with all applicable zoning, building, electrical, plumbing and mechanical ordinances of the City of Little Rock and the State of Arkansas. I or we further agree to abide by the applicable conditions as printed on the permit card. I or we further certify that we have read and understand the requirements of this permit and that all statements made by us in securing this permit are true and complete to the best of our knowledge. Permit Fees: Data Processing $4.00 Mechanical Permit Fees $31.00 Total: $35.00 Issued by: SSTEELE Licensed Contractor or Owner For: Charles G. Givens Building Official To schedule Mechanical inspections call: 501-918-5292 or 501-918-5282 City of Little Rock EKCITY OF LITTLE ROCK DEPARTMENT OF PLANNING & DEVELOPMENT BUILDING CODES DIVISION APPLICATION FOR: 723 WEST MARKHAM, 2ND FL MECHANICAL (HVACR) PERMIT LITTLE ROCK, AR 72201 PHONE (501) 918-5282 OR (501) 918-5292 FAX: 5 01 371-4546 INSPECTIONS INSPECTOR'S COMMENTS OFFICIAL USE ONLY APPLICANT (Please Check) PERMIT N0.201g ()CA I3 [:]WILLCALL ❑ROUGH DATE ISSUED IZL511 1 l5 ❑SLAB ❑ FINAL ISSUED BYS ❑OTHER PROJECT ADDRESS: 2806 DAISY L GASTON BATES DR. PROJECT NO. LEGAL DESCRIPTION' LOT BLOCK OWNER/TENANT: (Same as Building Permit No.) SUBDIVISION TELEPHONE: (�01) 993-6323 s i ADDREIs. 23419 GREYSTONE MANOR DR. LR AR 72223 FAX: CONTRACTOR: JONES HEATING & AIR LICENSE NO.: TURNER & SON CONSTRUCTION 520 EDISON BENTON AR 72015 CLASS OF WORK: []NEW ❑ADDITION []REPLACEMENT PROPOSED USE (OCCUPANCY): I__I COMMERCIAL ❑ RESIDENTIAL 133032 TELEPHONE/FAX (50T)'778-3324 ❑ ALTERATION 11 [-]OUT OF CITY ❑ MODULAR/MOBILE HOME ❑ BOILER - SQUARE FEET- 1450 VALUATION: 8,200 Heating/Air Mechanical Permit Fees: A. New one and two-family DWELLING Construction - $.0825/sqft (INCLUDES ROUGH_& FINAL INSPECTIONS) OTHER OCCUPANCIES B. Replacements, repairs, alterations and additions and new commercial -- heating, ventilation, ductwork, air conditioning, ,oilers', and refrigeration systems shall be as follows: $31.00 for the first $500.00 up to $1,000 plus $5.15 for each addit€anal thousand or fraction thereof to -and including $500,000.00. $2,569.85 for the first $600,000 plus $4.10 for each additional thousand or fraction thereof, yo A ihclvoing $1,000,000. • $4,619.86 for the first $1,000,000 plus $3.09 for each additional thousand or fraction thereof THESE PRICES INCLUDE ONLY ONE INSPECTION; ADDITIONAL INSPECTIONS ARE $20.50 EACH: Minimum fee for any permit shall be $31.00. Additional fee for Data Processing: $4.00 (resident€al),$6.00 (comm.) NO. Of Heating Units: 2 NO. Of Air -Conditioning Units- 2 Ductwork: QYes f ❑ No (ALL DUCTWORK REQUIRES A ROUGH INSPEC770llfy Commercial Ventilation System Commercial Refrigeration Split System No. Of Inspections P CHECK ONE OR MORE BELOW: DElectricOGas Fired ❑r Split System❑Package Unit❑Water Source ❑Condenser Coil[]Condenser ❑Evaporative Coll []Other (Explain) NOTE: BOILER PERMITS ARE ISSUED WITH PROOF OF SPECIAL BOILER LICENSE Penalties (Working without a permit): Where work for which a permit is required by the 2010 Arkansas Mechanical payment of such triple fee shall not relieve an person from fully complying with the requirements of the 2010 Arkansas Mechanical Code in the execution of the work nor from any penalties prescribed herein ar no additional permits shall be granted unfit all fees have been paid. NOTICE: SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, GAS, PLUMBING AND HVACR WORK. I hereby certify that the data submitted on or with this application is true and correct Any deviation from information cpntained herein, Unless approved by the Building Official will render this permit null and void. BRYAN O'NEAL SIGNATURE OF CONTRACTOR, OWNER OR AGENT 02/05/2018: DATE REV 1115 r: Ceiling R Value No Insulation R-11 R-19 R-30 R-38 Floor R Value No Insulation Carpet No Insulation R-11 R-19 R-30 Sq. Ft. 0 Ceiling Ht. 0 Mechanical Ventilation # People # Kitchens #Computers Other R-4 Insulation CEILING BTU GAIN Net Sq Ft Factor 0 21.4 0 4.1 0 2.6 1450 1.6 0 1.3 TOTALS FLOOR BTU GAIN Net Sq Ft Factor 720 7.7 0 5.1 0 1.7 0 1.1 0 0.7 TOTALS INFILTRATIONIVENTILATION BTU GAIN Factor Cu. Ft. 0 CFM 0 27 CFM 50 27 TOTALS INTERNAL BTU GAIN Factor 300 1200 500 Factor 0.1 TOTALS SP SUB TOTALS DP SUB TOTALS DUCT BTU GAIN SP TOTAL SENSIBLE HEAT GAIN DP TOTAL SENSIBLE HEAT GAIN LATENT LOAD CALCULATIONS Latent Load Infiltratrion Latent Load Ventilation # People 2 Tons Req, 4.0 SP Windows Tons Req, 3.7 DP windows TOTALS Total BTU's Required With SP Windows Total BTU's Required With DP Windows Page 2 Ceiling BTU Gain 0 0 0 2320 0 i- 32,0 Floor BTU Gain 5544 0 0 0 0 5544 I / V BTU Gain 0 1350 .1350 In.tiernal BTU Gain 900 1200 0 0 2100 45673 41182 Duct BTU Gain 5.07 46181 41690 0 1:700 1460 2160 48341 43850 MANUEL J LOAD Page 1 LOAD CALCULATOR Project: TURNER & SON CONST. Outdoor Temp.': 95 Date: 2/5/2018 Indoor Temp. 70 Area: 2806 DAISY L GASTON BATES DR. Temp. Difference 25 SENSIBLE LOAD CALCULATIONS GLASS BTU GAIN Direction Area Sq. Ft. Single Double SP BTU Gain DP BTU Gain N 96 37 26 3552 2496 NE&NW 0 70 56 0 0 E&W 131 95 76 12445 9956 SE&SW 0 82 66 0 0 S 86 52 41 4472 3526 TOTALS 313 TOTALS 20469 15978 DOORS & STAIRWELL BTU GAIN # Doors Area Sq. Ft. Factor Stairwells Door BTU Gain. Stairwell BTU Loss 2 72 9.6 1 .691 6000 TOTALS 6691 WALLS BTU GAIN Wall Length 313 Wall Height 10 Total Wall Sq. Ft. 3130 Net Wall Sq. Ft. 2745 Frame Walls R Value Net Sq Ft Factor F Wall; 8TU Gain No Insulation 0 7.8 0 R-11 0 2.6 `-0 R-13 3130 2.3 7199 R-13+1" Polystyrene 0 1.7 ; �1. 0 R-19+1 /2" Polystyrene 1.6 0 TOTALS 7199 Masonry Walls R Value Net Sq Ft Factor M Wall BTU Gain No Insulation 0 10•9 0 R-5 0 3.1 0 R-11 0 1.6 0 R-19 0 1 0 TOTALS 0 SP Glass Sensible Heat Gain Subtotal 34359 DP Glass Sensible Heat Gain Subtotal 29868