HomeMy WebLinkAboutZ-10064 Staff ReportITEM NO.: 16 FILE NO.: Z-10064
NAME: Rezoning from R-2 to R-4
LOCATION: 45 lots along Mountain Vista Drive and Summit View Drive
DEVELOPER:
APEX Professional Construction, LLC
32 Caurel Court
Little Rock, AR 72223
OWNER/AUTHORIZED AGENT:
Ryan Brooks, APEX Professional Construction, LLC – Owner
Kendel Grooms and Parker Spaulding - Agents
SURVEYOR/ENGINEER:
Bond Consulting Engineers, Inc.
2601 T.P. White Drive
Jacksonville, AR 72076
AREA: 18.05 acres NUMBER OF LOTS: 45 FT. NEW STREET: 0 LF
WARD: 7 PLANNING DISTRICT: 16 CENSUS TRACT: 41.04
CURRENT ZONING: R-2
VARIANCE/WAIVERS: None requested.
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant proposes to rezone 45 lots of the 57 lots in the Vista Pointe subdivision from “R-2” Single-family District to “R-4” Two-family district.
B. EXISTING CONDITIONS:
The Vista Pointe subdivision is platted with 57 lots. Twelve are currently occupied by residences. The remaining lots are undeveloped. Mountain Vista Drive is the only access to the
subdivision and is connected to Skyline Drive in Saline County.
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property located within 300 feet of the site and all neighborhood associations registered with the City of Little Rock were notified of the public hearing.
D. ENGINEERING COMMENTS:
Plan is not legible resubmit.
Secondary access is required for Fire and Police use.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comment.
Entergy: No comments received.
Summit Utilities: No comments.
AT & T: No comments received.
Central Arkansas Water: No comments.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where
a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent
in grade except as approved by the fire chief. If the grade exceeds 10 percent, approval will be denied and the applicant must submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of
buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed
load of fire apparatus weighing at least 75,000 pounds.
County Planning: No comments.
F. BUILDING CODES/LANDSCAPE:
Building Codes: No comments received.
Landscape: No comments.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division:
The request is in the Otter Creek Planning District. The Land Use Plan shows The Residential Low Density (RL) category provides for single family homes at densities not to exceed 6
dwelling units per acre. Such residential development is typically characterized by conventional single-family homes but may also include patio or garden homes and cluster homes, provided
that the density remains less than 6 units per acre for the requested area. The application is to rezone from R-2 to R-4.
Surrounding the application area are undeveloped tracts in RL.
This site is not located in an Overlay District
Master Street Plan:
Mountain Vista Drive is a Local Street on the Master Street Plan. Local Streets are roads designed to provide access to adjacent property with the movement of traffic being a secondary
purpose. The standard Right-of-way is 50’. Sidewalks are required on one side. This street may require dedication of right-of-way and may require street improvements.
Bicycle Plan:
Mountain Vista Drive is not shown on the Master Bike Plan with existing or proposed facilities in this area.
Historic Preservation Plan:
The application, as shown, should have no effect on identified historic resources.
H. ANALYSIS:
The applicant proposes to rezone 45 lots of the 57 lots in the Vista Pointe subdivision from “R-2” Single-family District to “R-4” Two-family district.
The Vista Pointe subdivision is platted with 57 lots. Lots 2, 3, 13, 18, 24, 27, 30, 32, 42, 46, 48, and 56 are currently occupied by single-family residences. The remaining lots are
undeveloped. Mountain Vista Drive is the only access to the subdivision and is connected to Skyline Drive in Saline County.
The request is in the Otter Creek Planning District. The Land Use Plan shows The Residential Low Density (RL) category provides for single family homes at densities not to exceed 6
dwelling units per acre. Such residential development is typically characterized by conventional single-family homes but may also include patio or garden homes and cluster homes, provided
that the density remains less than 6 units per acre for the requested area.
The applicant’s intent is to construct two-story, town house style duplexes on the 45 undeveloped lots. The proposed 1464 square feet town houses are designed to match the character
of the existing homes. Each townhouse is designed with a one-car garage and independent driveway access.
Staff is not supportive of the requested rezoning from R-2 to R-4. Staff does not feel it is appropriate to double the density of the subdivision. Doubling the density does not fit the
Land Use Plan and would put stress on the existing infrastructure. Additionally, having only one entrance to the subdivision poses safety concerns due to the difficulty of emergency
response vehicle access.
I. STAFF RECOMMENDATION:
Staff recommends denial of the requested rezoning from R-2 to R-4.